The technology of a condition based maintenance of an overhead contact line with Markov approximation of contact wire wear
Keywords:
overhead contact line,contact wire, mainanance technology, controlling action modelsAbstract
The technologies of OCL condition based maintenance were improved for providing reliable and economic current collecting on electrified railways and in traction power networks of urban electric transport. It is established that one of the most perspective methods of reducing operating costs is the transition to scientifically justified terms of repair and planning of works based on the actual state of OCL, the reliability of which is determined by the reliability, repair suitability and durability of the elements. The basic criteria of the current collecting process are proposed: the value of contacting pair wear, the detachment of the current collectors from the wires, the scope of oscillations of pantograph head and the contact pressure, coefficients of contact unreliability and cost savings of collecting a power from catenary, and, finally, a minimum of annual operating costs.
Technology of maintenance according to Markov type parameter control is developed. Models of controlling actions on stagger and the contact wire gradient adjustment processes are developed. The standard linear programming algorithm was used to solve the problem. The application of such technology to determine the matrix of controlling actions based on the results of monitoring the stagger and the contact wire gradient is shown. The factors that determine the cost of staying in a state of stagger have been identified. The controlling actions matrices on the stagger and the contact wire gradient and the cost of staying in these gradient states are established.
The technology of service with Markov approximation of wear of contact wires is offered. It has been investigated that the contact wires, primarily due to wear, are degraded during operation. Degradation processes cause gradual failures. The first group of failures: breakages, burnouts, local wear - require controlling actions to incut the insertion or putting into operation a shunt. The second group: a burnout, a decrease in the average cross-section of a wire less than the allowable one requires controlling actions to replace the wire of the entire tension length. After conducting the first type of controlling actions, the contact wire returns to the working state with the previous value of the determining parameter. When performing a second type of controlling actions, the defining parameter returns to its original state. If the quantification step is chosen such that the intensities of failures and transitions from one state to another with a sufficient degree of accuracy were constant, then the graph of states and transitions, as well as the Kolmogorov differential equations, can be used for the research. The readiness function, the density of time distribution of infallible operation, the total failure rate, and the average recovery rate from state to are determined. Thus, all reliability indicators are defined and it is possible to use them in determining the condition of the contact wire of the tension length.
Experience has shown that the most effective diagnostics of the condition of OCL devices combines the assessment of the state on mathematical, simulation models and measurements with the use of car laboratories for testing the contact network and devices for monitoring the parameters of the contact wire for the railcar.
References
Pravila ulashtuvannya ta tehnichnogo obslugovuvannya kontaktnoyi merezhi elektrifikovanih zaliznic. – K.: Inpres, 2008. – 208 s.
Miheev V.P. Kontaktnye seti i linii elektroperedachi / V.P. Miheev – M.: Marshrut, 2003. – 416 s. – (Uchebnik dlya vuzov zh. d. transporta).
Vologin V. A. Vzaimodejstvie tokopriemnikov i kontaktnoj seti / V. A. Vologin – M.: Intekst, 2006. – 256 s.
Efimov A. V. Nadezhnost i diagnostika sistem elektrosnabzheniya zheleznyh dorog /A. V. Efimov, A.G. Galkin. – M.: UMK MPS Rossii, 2000. – 512 s.
Kiessling F. Contact Lines for Electric Railways: Planning, Design, Implementation, Maintenance / F. Kiessling, R. Puschmann, A. Schmieder, E. Schmieder, 2-nd Edition, Berlin and Munich. Siemens, 2009. – 994 p.
Galkin A. G. Teoriya i metody rascheta processov proektirovaniya i tehnicheskogo obsluzhivaniya kontaktnoj seti: dis. ... d-ra tehn. nauk: 05.22.07 / Galkin Aleksandr Gennadevich. – Ekaterinburg, 2002. – 370 s.
Domanskij V. T. Koncepciya tehnichnogo obslugovuvannya pristroyiv elektropostachannya zaliznic za stanom na bazi yih diagnostiki i monitoringu / V. T. Domanskij, K. V. Pereverzyev // Ukrayinska zaliznicya. – 2019. № 3(69). – S. 9–13.
Pereverzyev K. V. Sovremennye metody i sredstva diagnostiki kontaktnyh setej elektrificirovannyh zheleznyh dorog / K. V. Pereverzyev // Ukrayinska zaliznicya. – 2019. № 6(72). – S. 23–27.
Shimizu M. Development of Transition Structures between Overhead Rigid Conductor Line and Catenary-Type Contact Line / M. Shimizu, T. Kobayashi [et al.] // RTRI Report, Vol.21, No.10, pp. 29-34, October 2007, (in Japanese).
Shimizu M. Development of Transition Structures between Overhead Rigid Conductor Line and Catenary-Type Contact Line / M. Shimizu, T. Kobayashi, A. Oya // RTRI Report, Vol.49, No.2, pp. 103-107, May 2008, (in Japanese).
Downloads
Published
How to Cite
Issue
Section
License
The authors that are published in this journal agree with the following terms:
- The authors reserve the right of authorship of his work and pass to the journal the right of first publication of this work is licensed under a Creative Commons Attribution License, which allows others to freely distribute published work with reference to authors of original works and works first published in this journal.
- The authors have the right to enter into a separate additional agreement for non-exclusive distribution of work in the form in which it was published in the magazine (for example, to place work in electronic storage agencies or publish as part of the monograph), providing the reference to the first publication in this journal.
- Journal policy allows and encourages the placement by the authors on the Internet (eg, in storage facilities or personal websites) the manuscript of the works before the submission of the manuscript to the editor as well as during its editorial processing, as it contributes to productive scientific discussion and has a positive impact on efficiency and dynamics citing published work (see. The Effect of Open Access).