To the Problem of Protection of Medium Voltage Instrument Transformers with Fuses: Analytical Research

Authors

  • Yevgen Bajda National Technical University “Kharkiv Polytechnic Institute”, Ukraine
  • Oleksandr Grechko National Technical University “Kharkiv Polytechnic Institute”, Ukraine
  • Viktor Buhaichuk ABM Amper Ltd., Ukraine
  • Robert Knápek KPB Intra s.r.o., Czech Republic

DOI:

https://doi.org/10.33042/2079-424X.2021.60.3.02

Keywords:

Medium Voltage Instrument Transformer, Fuse, Voltage Transformer Protection, Instrument Transformer Primary Winding Current

Abstract

Introduction. In the medium voltage power grid of 6–35 kV, there is a problem of protecting voltage instrument transformers. This is due to the insufficiently effective level of their protection with fuses. Recently, there have been more and more reports of accidents associated with the failure of voltage instrument transformers not only in Ukraine, but also abroad. The issue of conducting an analytical study of the problem of protection of medium voltage instrument transformers by fuses is relevant. Goal. Investigation of designs and characteristics of fuses for medium voltage instrument transformers to improve the efficiency of their protection. Results. The article shows that protection of medium voltage instrument transformers with epoxy insulation is often provided by fuses, in which the nominal current of the fuse-link is significantly higher than the maximum permissible long-term current of the primary winding of the instrument transformer. A comparative analysis of the current values of the primary winding of medium voltage instrument transformers with the values of the rated currents of the fuse-links of fuses of various manufacturers presented on the Ukrainian market is carried out. The design features and technical characteristics of fuses for medium voltage instrument transformers have been investigated in order to increase the efficiency of their protection. The advantages and disadvantages of the designs of fuses from various manufacturers have been investigated and it has been established that the design of fuses requires further improvement in order to increase the efficiency of protection of medium voltage instrument transformers. Discussion and prospects for further development. Since in Ukraine, the need for fuses to protect medium voltage instrument transformers is provided mainly by supplies abroad, a promising direction for further development in this direction is the creation of a domestic competitive design of a fuse and its introduction into production.

Author Biographies

Yevgen Bajda, National Technical University “Kharkiv Polytechnic Institute”, Ukraine

D.Sc., Associate Professor of the Department of Electrical Apparatus

Oleksandr Grechko, National Technical University “Kharkiv Polytechnic Institute”, Ukraine

Ph.D., Associate Professor of the Department of Electrical Apparatus

Viktor Buhaichuk, ABM Amper Ltd., Ukraine

Chairman of the Supervisory Board

Robert Knápek, KPB Intra s.r.o., Czech Republic

Company Director

References

Tugai, Y.I., & Tugai, I.Y. (2014). A combined method for study of ferroresonance processes in voltage transformer. In 2014 IEEE International Conference on Intelligent Energy and Power Systems (IEPS) (pp. 71–73). IEEE. https://doi.org/10.1109/IEPS.2014.6874205

Tugay, Y.I., Ganus, O.I., & Starkov, K.O. (2016). The switching in voltage transformer. Technical Electrodynamics, 2016(5), 73–75. https://doi.org/10.15407/techned2016.05.073

Zhurahivskyi, A.V., Kens, Y.A., Yatseyko, А.Y., & Maslyak, R.Y. (2010). Ferroresonance processes in electrical networks 10 kV with different voltage transformers. Technical Electrodynamics, (2), 73–78. http://previous.techned.org.ua/article/10-2/st9.pdf (in Ukrainian)

Ryzhkova, Y.N., & Tsyruk, S.A. (2016). Ferroresonance suppression in distribution networks. In 2016 2nd International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM) (pp. 1–4). IEEE. https://doi.org/10.1109/ICIEAM.2016.7911458

Jahagirdar, A., Thosar, A., & Dhote, V.P. (2018). Study of high voltage inductive voltage transformer for transients and ferroresonance. In 2018 International Conference on Power, Energy, Control and Transmission Systems (ICPECTS) (pp. 174–180). IEEE. https://doi.org/10.1109/ICPECTS.2018.8521570

Hanus, O., & Starkov, K. (2021). Study of the nature of overvoltages in the electrical network arising from voltage transformers. Bulletin of the National Technical University “KhPI”. Series: Energy: Reliability and Energy Efficiency, 1(2), 28–36. https://doi.org/10.20998/2224-0349.2021.01.05 (in Ukrainian)

Kaczmarek, M., & Brodecki, D. (2021). Transformation of transient overvoltages by inductive voltage transformers. Sensors, 21(12), 4167. https://doi.org/10.3390/s21124167

McDermit, D.C., Shipp, D.D., Dionise, T.J., & Lorch, V. (2013). Medium-voltage switching transient-induced potential transformer failures: prediction, measurement, and practical solutions. IEEE Transactions on Industry Applications, 49(4), 1726–1737. https://doi.org/10.1109/TIA.2013.2258453

Dan, M., Zanotto, L., Gaio, E., Panizza, C., Finotti, C., & Perna, M. (2021). Development and validation of a special protection system for internal fault in a high-power three-level NPC VSC. Energies, 14(18), 5937. https://doi.org/10.3390/en14185937

Zhurahivskyi, A.V., Kens, Y.A., Yatseyko, A.Y., & Maslyak, R.Y. (2013). Multi-protection system power grids 6–35 Kv from ferroresonance processes. Technical Electrodynamics, (5), 70–76. http://previous.techned.org.ua/2013_5/st11.pdf (in Ukrainian)

Ganus, O., & Starkov, К. (2003). Damageability of voltage transformers in regional electricity networks of JSC “Kharkovoblenergo” and measures to reduce it. Lighting Engineering & Power Engineering, (1), 75–81. (in Russian)

Xue, S., Sun, W., Yang, J., Gao, F., Li, Y., & Li, Z. (2016). Hidden failure identification and protection of multi-grounding fault in secondary circuit of potential transformer. IEEJ Transactions on Electrical and Electronic Engineering, 11(3), 300–307. https://doi.org/10.1002/tee.22219

Heidary, A., Rouzbehi, K., Radmanesh, H., & Pou, J. (2020). Voltage transformer ferroresonance: an inhibitor device. IEEE Transactions on Power Delivery, 35(6), 2731–2733. https://doi.org/10.1109/TPWRD.2020.3005321

Cazacu, E., Ioniţă, V., & Petrescu, L. (2017). An efficient method for investigating the ferroresonance of single-phase iron core devices. In 2017 10th International Symposium on Advanced Topics in Electrical Engineering (ATEE) (pp. 363–368). IEEE. https://doi.org/10.1109/ATEE.2017.7905167

Niu, B., Wu, X., Zhang, G., Ma, F., Tan, D., & He, S. (2020). Analysis and improvement measures of inductive voltage transformer fault caused by intermittent grounding. Gaoya Dianqi/High Voltage Apparatus, 56(10), 70–74 & 83. https://doi.org/10.13296/j.1001-1609.hva.2020.10.012

Kaczmarek, M. (2016). Secondary current distortion of inductive current transformer in conditions of dips and interruptions of voltage in the power line. Electric Power Systems Research, 137, 1–5. https://doi.org/10.1016/j.epsr.2016.03.043

Popov, M. (2018). General approach for accurate resonance analysis in transformer windings. Electric Power Systems Research, 161, 45–51. https://doi.org/10.1016/j.epsr.2018.04.002

Lesniewska, E., Kaczmarek, M., & Stano, E. (2021). 3D electromagnetic field analysis applied to evaluate the accuracy of a voltage transformer under distorted voltage. Energies, 14(1), 136. https://doi.org/10.3390/en14010136

Etkind, L. (2003). Protection of voltage transformers in 3–35 kV networks. Neutral earthing mode needs to be changed. Electrical Engineering News, (5), 6. http://news.elteh.ru/arh/2003/23/06.php (in Russian)

Hejian, W., Hongtao, L., Tao, G., Jun, J., Hailong, Z., & Song, J. (2018). Research and application of 10 kV built-in high voltage protection distribution transformer. In 2018 China International Conference on Electricity Distribution (CICED) (pp. 280–284). IEEE. https://doi.org/10.1109/CICED.2018.8592468

Ventruella, D.J. (2018). Transformer fuse sizing – the NEC is not the last word. IEEE Transactions on Industry Applications, 55(2), 2173–2180. https://doi.org/10.1109/TIA.2018.2880145

Liang, Z., Zhao, M., Niu, S., Liu, H., Liang, S., & Guo, Y. (2016). Defects of measures against PT fuse melting in distribution network and research of new measure. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 36(9), 17–24 & 32. https://doi.org/10.16081/j.issn.1006-6047.2016.09.003

Wang, K., Liu, H., Yang, Q., Yin, L., & Huang, J. (2019). Impact transient characteristics and selection method of voltage transformer fuse. Energies, 12(4), 737. https://doi.org/10.3390/en12040737

Pleşca, A., Dumitrescu, C., Zhang, G., & Han, D. (2016). Overcurrent protection using a new type of electric fuse. In 2016 International Conference and Exposition on Electrical and Power Engineering (EPE) (pp. 143–146). IEEE. https://doi.org/10.1109/ICEPE.2016.7781321

Kim, S., Shin, T., Jeong, S., Kang, H., Son, K., Park, S., ... & Kim, J. (2020). Modeling and verification of a high voltage fuse for high reliability and safety in electric vehicle. In 2020 IEEE International Symposium on Electromagnetic Compatibility & Signal/Power Integrity (EMCSI) (pp. 287–292). IEEE. https://doi.org/10.1109/EMCSI38923.2020.9191482

Ventruella, D.J. (2020). Transformer fuses – mind the gap. IEEE Transactions on Industry Applications, 56(5), 5670–5677. https://doi.org/10.1109/TIA.2020.2993523

Wright, A., & Newbery, P.G. (2004). Electric Fuses (3rd ed.). Institution of Electrical Engineers. https://doi.org/10.1049/PBPO049E

Wang, M., Chen, W., Li, Y., Zhang, X., Dong, B., Bian, K., ... Deng, F. (2012). A countermeasure to deal with abnormal fusing of high voltage fuse for potential transformer in 35 kV oilfield power distribution system. Dianwang Jishu/Power System Technology, 36(12), 283–288.

Torres, E., Fernandez, E., Mazon, A.J., Zamora, I., & Perez, J.C. (2005). Thermal analysis of medium voltage fuses using the finite element method. In 2005 IEEE Russia Power Tech (pp. 1–5). IEEE. https://doi.org/10.1109/PTC.2005.4524671

Plesca, A. (2018). Temperature distribution of HBC fuses with asymmetric electric current ratios through fuselinks. Energies, 11(8), 1990. https://doi.org/10.3390/en11081990

International Electrotechnical Commission. (2014). Low-voltage fuses – Part 1: General requirements (IEC Stand-ard No. 60269-1:2006 + AMD1:2009 + AMD2:2014 CSV Consolidated version). https://webstore.iec.ch/publication/1234

International Electrotechnical Commission. (2020). High-voltage fuses – Part 1: Current-limiting fuses (IEC Standard No. 60282-1:2020). https://webstore.iec.ch/publication/59817

Němeček, P. (2009). Proudová ochrana pro vysoko-napěťové transformátory (CZ patent No. 20024 U1). Úřad průmyslového vlastnictví. https://patents.google.com/patent/CZ20024U1

Downloads

Published

2021-12-30

How to Cite

Bajda, Y., Grechko, O., Buhaichuk, V., & Knápek, R. (2021). To the Problem of Protection of Medium Voltage Instrument Transformers with Fuses: Analytical Research. Lighting Engineering & Power Engineering, 60(3), 92–102. https://doi.org/10.33042/2079-424X.2021.60.3.02